Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Rev. biol. trop ; 69(3)sept. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1387665

ABSTRACT

Abstract Introduction: Enough scientific evidence is available on the harmful effects of air pollution on the health of human beings, fauna, flora, and ecosystems in general. The mechanical and electronical monitoring networks are the first option for the air quality diagnosis, but they do not allow a direct and precise assessment of the impacts in living organisms that may result from the exposure to air pollutants. Objective: To evaluate the changes in the composition of corticulous lichen communities as a response to various stress factors in areas with different levels of air quality to diagnose the state of pollution or intervention in an area with a more complete option. Methods: Air quality contrasts and changes in richness and coverage of corticulous lichens in response to different stress factors, such as land use and distance to roads, in three different biomonitoring areas, were evaluate using GIS, and the data are presented in an easy-to-understand grey scale coded isoline map. Results: Indicators such as lichen coverage (R= -0.4) and richness (R= -0.7) are inverse correlated with PM2.5 concentrations in each area. A total of 110 lichen species were identified, being Phaeophyscia chloantha (Ach.) Moberg and Physcia poncinsii Hue the most frequent species (present in 38 and 33 % of the 86 sampled phorophytes, respectively). The intra-area relationships of lichen richness exhibit significant relationships with regards to the land use and distance to roads (with correlations coefficients greater than 0.5) and the Simpson index was higher than 0.9, in places with better conditions in terms of air quality and microenvironments, likewise the resistance factors calculated suggest that the most sensitive species can be found in environments with a lesser degree of disturbance. Conclusion: These evaluations represent more criteria elements for the diagnosis of the environmental health in the biomonitoring areas.


Resumen Introducción: Existe suficiente evidencia científica de los efectos nocivos de la contaminación atmosférica sobre la salud de los seres humanos, fauna, flora y ecosistemas en general. La primera opción para el diagnóstico de la calidad del aire son las redes de monitoreo mecánicas o electrónicas, pero estas no permiten evaluar de forma directa y precisa el impacto en los organismos vivos como resultado de la exposición a contaminantes del aire. Objetivo: Evaluar los cambios en la composición de las comunidades de líquenes cortícolas como resultado a la exposición de factores de estrés ambiental en áreas con diferentes niveles de calidad del aire para diagnosticar el estado de contaminación o intervención en una zona de una manera más completa. Métodos: Se determinaron los contrastes y cambios en la calidad del aire, la riqueza y cobertura de líquenes cortícolas en respuesta a diferentes factores de estrés, como usos del suelo y distancia a carreteras, en tres diferentes áreas de biomonitoreo, las cuales fueron evaluadas usando GIS. Los datos se presentan en un mapa de isolíneas con códigos en escala de grises fácil de entender. Resultados: Indicadores como cobertura (R= -0.4) y riqueza (R= -0.7) de líquenes están inversamente correlacionados con las concentraciones de PM2.5 en cada área. Se identificaron un total de 110 especies de líquenes, siendo Phaeophyscia chloantha (Ach.) Moberg y Physcia poncinsii Hue las especies más frecuentes (presentes en 38 y 33 % de los 86 forófitos muestreados, respectivamente). Las relaciones intra-área de riqueza de líquenes exhiben relaciones significativas con respecto al uso del suelo y distancia a carreteras (con coeficientes de correlación mayores a 0.5) y el índice de Simpson fue mayor a 0.9, en lugares con mejores condiciones en términos de calidad del aire y microambientes. Asimismo, los factores de resistencia calculados sugieren que las especies más sensibles se pueden encontrar en ambientes con menor grado de perturbación. Conclusión: Estas evaluaciones representan más elementos de criterio para el diagnóstico de la salud ambiental en las áreas de biomonitoreo.


Subject(s)
Air Pollutants , Lichens , Colombia
2.
Rev. Univ. Ind. Santander, Salud ; 53(1): e302, Marzo 12, 2021. tab, graf
Article in Spanish | LILACS | ID: biblio-1365444

ABSTRACT

Resumen Introducción: La exposición de largo y corto plazo a determinadas concentraciones de contaminantes ambientales parece incidir en la propagación y agravamiento de la COVID-19. Por otra parte, se ha hipotetizado que las cuarentenas tienen un efecto positivo en la calidad del aire. Objetivo: Examinar la concentración de material particulado 10 (CPM10) en los últimos cinco años; en meses precuarentena y postcuarentena de 2020 y el impacto de la cuarentena en la CPM10 en Santa Marta (Colombia). Materiales y Métodos: Estudio retrospectivo de corte longitudinal, sobre la CPM10 en una muestra de cinco estaciones de monitoreo ambiental, periodo 2016 - 2020. Se calcularon distribuciones de CPM10 por año y estación, así como entre meses pre y postcuarentena. Resultados: Se evidenció una reducción estadísticamente significativa del CPM10 en 2020 respecto a los cuatro años anteriores, cercana al 34 %; lo propio sucedió para meses postcuarentena versus precuarentena, con disminución del 40 % en los primeros. No hubo diferencias significativas de CPM10 entre las estaciones, aunque se observaron medianas superiores del contaminante en las del sur. La CPM10 de 2016 - 2020 (largo plazo) y en meses precuarentena (corto plazo) sobrepasaron los límites de riesgo aumentado de morbimortalidad por COVID-19 establecidos en estudios internacionales previos. Conclusión: La cuarentena tuvo un impacto positivo en la calidad del aire en Santa Marta. No obstante, los niveles de CPM10 encontrados a largo y corto plazo pudieron haber predispuesto a la población al contagio y fallecimiento por el virus.


Abstract Introduction: Long and short-term exposure to certain concentrations of environmental pollutants seems to influence the spread and worsening of COVID-19. On the other hand, it has been hypothesized that quarantines have a positive effect on air quality. Objective: To examine the concentration of particulate material 10 (CPM10) in the last five years, in pre-quarantine and post-quarantine months of 2020 and the impact of the quarantine on CPM10 in Santa Marta (Colombia). Materials and Methods: Retrospective longitudinal study of CPM10 on a sample of five environmental monitoring stations, period 2016-2020. CPM10 distributions were calculated for each year and season, as well as between months before and after quarantine. Results: A statistically significant reduction of 34% in CPM10 was evidenced in 2020 compared to the previous four years. CPM10 of post-quarantine months decreased 40% in comparison with the pre-quarantine months. There were no significant differences in CPM10 between the stations, although median values of CPM10 were higher in the southern stations. CPM10 from 20162020 (long term) and in pre-quarantine months (short term) exceeded the limits of increased risk of morbidity and mortality from COVID-19 established in previous international studies. Conclusion: The quarantine had a positive impact on the air quality in Santa Marta. However, CPM10 levels found in the long and short term could have predisposed the population to infection and death from the virus.


Subject(s)
Humans , Air Pollution , Particulate Matter , COVID-19 , Quarantine , Environmental Monitoring , Colombia
3.
Bol. malariol. salud ambient ; 61(2): 318-327, 2021. tab, graf
Article in Spanish | LILACS, LIVECS | ID: biblio-1411865

ABSTRACT

atmosférica es responsable de 6.67 millones de muertes al año por accidentes cardiovasculares, enfermedades cardíacas, cáncer de pulmón y enfermedades respiratorias crónicas (HEI, 2020; OMS, 2021). La presente investigación determino la calidad del aire en la ciudad San Francisco de Milagro y su influencia en la salud poblacional. Los esultados expresan, que la concentración promedio de estos gases están dentro delos estándares establecidos por la OMS (2005), OMS (2018); para cada uno de ellos y por ende no son dañinos para la salud de la población en esudio. Sin embargo, actividades de desarrollo local como el caso de obras de construcción, estarían causando molestias en la población, debido a la falta de control y regulación ambiental, como lo demostró el estudio de percepciones(AU)


Environmental pollution is a global health problem with serious negative implications for humans. According to the WHO, air pollution is responsible for 6.67 million deaths per year from cardiovascular accidents, heart disease, lung cancer and chronic respiratory diseases (HEI, 2020; WHO, 2021). This research determined the air quality in the city of San Francisco de Milagro and its influence on population health. The results express that the average concentration of these gases are within the standards established by the WHO (2005), WHO (2018); for each of them and therefore are not harmful to the health of the population under study. However, local development activities such as construction works would be causing inconvenience to the population, due to the lack of environmental control and regulation, as the perceptions study showed(AU)


Subject(s)
Humans , Male , Female , Air Pollution , Cardiovascular Diseases , Environmental Health , Air Pollutants
4.
Santa Tecla, La Libertad; ITCA Editores; ene. 2020. 74 p. ^c28 cm.ilus., graf..
Monography in Spanish | LILACS, BISSAL | ID: biblio-1222793

ABSTRACT

Se construyeron e instalaron en coordinación con la UTEC, 3 estaciones de monitoreo de calidad del aire en ITCA-FEPADE Santa Tecla, San Miguel y La Unión. Estos dispositivos miden el nivel de contaminación del aire por material particulado de 2.5 y 10 micras de diámetro en las zonas donde están instalados. ITCA-FEPADE desarrolló un software de interpretación y predicción de dato de contaminación ambiental con Big Data y Machine Learning. Los datos de las estaciones son capturados en formato Big Data, los cuales son procesados por medio de una plataforma web diseñada, en donde se grafica el estado de la calidad del aire según la zona seleccionada. Se desarrolló además, un algoritmo de Machine Learning, el cual realiza una predicción de la calidad del aire para el término de un mes. Según aumente la cantidad de muestras así será el potencial de predicción para un día, semana, mes o año. La aplicación de los resultados de este proyecto con la construcción de más estaciones de monitoreo, permitirá lograr una cobertura a nivel nacional y medir con más detalle la calidad del aire que se respira en El Salvador, logrando así mejorar la toma de decisiones respecto al combate de la contaminación del aire y de las enfermedades respiratorias


In coordination with Universidad Tecnológica de El Salvador (UTEC), 3 air quality monitoring stations were built and installed at Escuela Especializada en Ingeniería ITCA-FEPADE Santa Tecla, San Miguel and La Unión. These devices measure the level of air pollution by particulate matter of 2.5 and 10 microns in diameter in the areas where they are installed. ITCA-FEPADE developed a software for interpretation and prediction of environmental pollution data with Big Data and Machine Learning. The data from the stations is captured in Big Data format, which is processed through a designed web platform, where the state of air quality is plotted according to the selected area. In addition, a Machine Learning algorithm was developed, which makes a prediction of air quality for the term of one month. As the number of samples increases, so will the prediction potential for a day, week, month or year. The application of the results of this project with the construction of more monitoring stations, achieve national coverage and measure in more detail the quality of the air that is breathed in El Salvador, thus improving decision-making regarding the combat of air pollution and respiratory diseases


Subject(s)
Software , Air Quality Control , Total Quality Management , Air Pollution , Monitoring Stations , Environmental Monitoring , Environmental Pollution
5.
Rev. salud pública ; 20(1): 126-131, ene.-feb. 2018.
Article in Spanish | LILACS | ID: biblio-962102

ABSTRACT

RESUMEN La movilidad motorizada está íntimamente ligada a los combustibles líquidos como la gasolina y el diésel; y en consecuencia, con el medio ambiente. Además de la problemática con el calentamiento global, la utilización de estos combustibles genera compuestos de carácter contaminante que afecta la salud de la población. Entre todos los contaminantes criterio, el material particulado (PM) de tamaño menor o igual a 2,5 micras (PM25) es considerado como uno de los compuestos de mayor peligrosidad debido a que puede penetrar hasta la región de intercambio de gases del pulmón. Los registros para el Área Metropolitana del Valle de Aburrá (AMVA) muestran eventualmente que los niveles promedio de calidad del aire resultan ser nocivos para la salud del habitante metropolitano. Lo anterior se debe principalmente a las altas concentraciones de PM25 generadas por vehículos pesados que usan combustible diésel. Si bien las propiedades de este combustible tienen un efecto directo en el PM respirable, existen otras estrategias que influyen en las características y la cantidad de las emisiones generadas. Por ejemplo, la mejora del nivel tecnológico de los motores a partir de planes de chatarrización y renovación, y de la pauta de conducción, así como la incorporación de vehículos eléctricos. Con todo lo anterior, este trabajo muestra una serie de consideraciones a fin de plantear posibles estrategias de solución a la problemática ambiental de la ciudad y el país.(AU)


ABSTRACT Motorized mobility is closely linked to liquid fuels such as gasoline and diésel and therefore, to the environment. Besides the problems associated with global warming, the use of these fuels also generates polluting compounds affecting the population health. Among all primary pollutants, particulate matter (PM) less than or equal to 2.5 microns (PM25) in size, is regarded as one of the most dangerous compounds because it can penetrate the region lung gas exchange. The records for the Área Metropolitana del Valle de Aburrá (AMVA) often show that the average levels of air quality were found to be harmful to the health of metropolitan habitants. This is mainly attributed to the high concentrations of PM25 generated by heavy-duty vehicles that use diésel fuel. Although the properties of diesel fuel have a direct effect on breathable PM, there are other strategies influencing both nature and amount of emissions. For example, the improvement of the technological level of the engines and the driving pattern, as well as the incorporation of electric vehicles. This paper shows some considerations in order to propose possible strategies to solve the environmental problem of the city and the country.(AU)


Subject(s)
Air Quality Control , Air Pollutants/adverse effects , Fossil Fuels/adverse effects , Population Health , Colombia , Motor Vehicles
6.
Rev. salud pública ; 19(4): 511-518, jul.-ago. 2017. tab
Article in Spanish | LILACS | ID: biblio-903138

ABSTRACT

RESUMEN Objetivos Comparar la percepción sobre calidad de vida y situación ambiental, en municipios próximos y distantes de la actividad minero industrial del Departamento de Boyacá. Método Estudio epidemiológico transversal. Los municipios próximos al área de influencia fueron agrupados en zonas identificadas como 1 y 2, y los municipios distantes como zona 0. Se realizó un muestreo aleatorio simple, multietápico, por conglomerados. Se determinó una muestra de 1 117 hogares y la unidad de análisis fue la familia. Para medir la calidad de vida y percepción de salud se utilizó el instrumento WHOQOL-BREF. Se calcularon distribuciones de frecuencia, diferencias entre variables y comparaciones entre variables cualitativas y cuantitativas. Se realizaron análisis univariados y bivariados. Resultados La calificación de la calidad de vida y satisfacción con la salud es mayor en la zona 0. Las medias calculadas para los cuatro dominios del cuestionario, por municipios, muestra que Ramiriquí presenta los rangos intercuartílicos más elevados. La percepción de calidad de vida y salud disminuye a medida que aumenta la edad y se presentan resultados menos satisfactorios entre las mujeres. En las zonas 1 y 2, el medio ambiente del municipio se calificó como "muy malo" y la situación ambiental de su municipio sin ninguna mejora en los últimos cinco años Conclusión Las comunidades próximas a actividades minero-industriales, reportan una peor percepción de salud, mayor preocupación ante el riesgo a la exposición y no consideran que dicha actividad aporte mayores beneficios para su calidad de vida.(AU)


ABSTRACT Objective To compare the life quality perception and environmental situation, in nearby and distant towns from the mining industry of the Boyacá Department of Colombia Method Cross-sectional study. The towns near of influence area were grouped into zones 1 and 2, and distant towns as zone 0. Conglomerates carried out a simple, multistage, random sampling. A sample of 1,117 households was determined and the unit of analysis was the family. To measure the quality of life and health perception, the WHOQOL-BREF instrument was used. Frequency distributions and comparisons between qualitative and quantitative variables were calculated. Univariate and bivariate analyzes were performed. Results The life quality perception and satisfaction with health was greater in zone 0. The means calculated for the four domains of the questionnaire, by towns, shows that Ramiriquí has the highest interquartile ranges. The life quality perception decreases in women and with increasing age. In zones 1 & 2, the environment was described as "very bad" and without any improvement at the last five years. Conclusion Communities close to mining-industrial activities report a worse perception of health, greater concern about the risk of exposure and do not consider that mining industry provides greater benefits for their quality of life.(AU)


Subject(s)
Humans , Quality of Life , Air Pollution , Mining , Epidemiologic Studies , Cross-Sectional Studies , Colombia
7.
NOVA publ. cient ; 14(26): 103-111, July-Dec. 2016. ilus, tab
Article in Spanish | LILACS, COLNAL | ID: biblio-955173

ABSTRACT

Objetivo. Determinar las bacterias del aire de un laboratorio de enseñanza de microbiología de la Universidad Distrital y así establecer la posibilidad de riesgo para la salud a la exponen los usuarios por la presencia de estos microorganismos. Métodos. Se tomaron muestras de aire por la técnica de sedimentación, se realizaron recuentos, y caracterización macroscópica y microscópica de las colonias. Después de aislamientos selectivos se llevó a cabo identificación por BD BBL Crystal. Resultados. Se obtuvo mayor recuento de bacterias Gram positivas que de Gram negativas. Se encontraron bacterias de los géneros Micrococcus, Staphylococcus, Leuconostoc, Bacillus, Corynebacterium, Pseudomonas, Yersinia, Serratia, Shigella, Klebsiella, Citrobacter y Acinetobacter. Los resultados mostraron que las bacterias identificadas no suponen riesgo elevado para la salud de los usuarios sanos, pero que es necesario implementar medidas para disminuir la carga bacteriana y disminuir posibles afecciones generales en la salud de sus ocupantes.


Objective. Determine airborne bacteria in a teaching laboratory of microbiology at the Distrital University and establish the bacteriological quality of air which users are exposed. Methods. Air samples were taken by sedimentation technique. The recovered colonies were counted, macroscopic and microscopic characterized and culture in selective media. The isolates were identifies by BD BBL Crystal. Results. It was found greater counts of gram-positive bacteria compared with Gram negative. It was identified bacteria of genus Micrococcus, Staphylococcus, Leuconostoc, Bacillus, Corynebacterium, Pseudomonas, Yersinia, Serratia, Shigella, Klebsiella, Citrobacter and Acinetobacter. The results showed that the bacteria identified do not present high risk to healthy of users, but it is necessary to implement measures to reduce the bacterial presence. Additionally, in this way decrease possible impact in general health of its occupants.


Subject(s)
Humans , Bacteriology , Environmental Quality , Laboratories , Microbiology
8.
Rev. salud pública ; 18(3): 1-1, mayo-jun. 2016. ilus, tab
Article in Portuguese | LILACS | ID: lil-784964

ABSTRACT

Objetivo Avaliar a qualidade do ar das salas do centro cirúrgico de um hospital no Sul do Brasil. Métodos Foi realizada uma avaliação dos parâmetros de confortabilidade (temperatura, luminosidade, concentração de dióxido de carbono e umidade relativa do ar), análise microbiológica e cromatográfica do material particulado presente nos filtros dos aparelhos de ar condicionados. Resultados Em relação aos aspectos de confortabilidade, três salas cirúrgicas não apresentaram temperatura de acordo com a legislação vigente, mas encontram-se dentro do padrão ideal nos demais fatores ambientais. Na análise do material particulado, obteve-se um maior número de bioaerossóis fúngicos de colônias viscosas do que as filamentosas. Conclusões Constatou-se que os principais aspectos da qualidade do ar no hospital são atendidos, no entanto há a necessidade de modificação de aspectos construtivos nas salas de cirurgia para que se reduza a possibilidade de contaminações por via atmosférica e possa reduzir a concentração de dióxido de carbono no ambiente.(AU)


Objective The aim of this study was to evaluate the quality of air in surgical centre rooms of a hospital in the South of Brazil. Methods An evaluation of the parameters of comfortability (temperature, luminosity, concentration of carbon dioxide and relative humidity), microbiological analysis and chromatographic of the particulate material present in the filters of air conditioners was carried out. Results Regarding the aspects of comfortability, three surgical rooms did not present temperature in accordance to the current legislation, but were found within the ideal patterns in other environmental factors. In the analysis of particulate material, a larger number of fungal bio-aerosols of viscous colonies was obtained than filamentous. Conclusion It was found that the main aspects related to the quality of air in the hospital being studied are being accomplished; however there is a need of modifying building aspects in the surgical rooms in order to reduce the possibility of contamination by air and decrease the concentration of carbon dioxide in the environment.(AU)


Objetivo Evaluar la calidad del aire de las salas del centro quirúrgico de un hospital en el "Vale do Rio Pardo", en el sur de Brasil. Métodos Fue realizada una evaluación de los parámetros de confortabilidad (temperatura, luminosidad, concentración de dióxido de carbono y humedad relativa del aire), análisis microbiológico y cromatográfico del material particulado presente en los filtros de los aparatos de aire acondicionados. Resultados En relación a los aspectos de confortabilidad, tres salas quirúrgicas no presentaron temperatura de acuerdo con la legislación vigente, pero se encuentran dentro del padrón ideal en los demás factores ambientales. En el análisis del material particulado, se obtuvo un número más grande de bioaerosoles fúngicos de colonias viscosas de que las filamentosas. Conclusión Se constató que los principales aspectos relacionados a la calidad del aire en el hospital en estudio, son atendidos, sin embargo, ahí la necesidad de cambio de aspectos constructivos en las salas de cirugía para que se reduzca la posibilidad de contaminaciones por vía atmosférica y pueda reducir la concentración de dióxido de carbono en el ambiente.(AU)


Subject(s)
Operating Rooms/standards , Carbon Dioxide/analysis , Cross Infection/prevention & control , Air Pollution, Indoor/analysis , Brazil , Microbiological Techniques/instrumentation
9.
Rev. cient. (Guatem.) ; 25(2): [43]-[58], Noviembre 2015.
Article in Spanish | LILACS | ID: biblio-883379

ABSTRACT

Se determinó la calidad del aire en el interior y exterior de la Micoteca Licenciado Rúben Mayorga Peralta (MICG), el Herbario de Biología de Guatemala (Herbario BIGU), el Museo de Historia Natural (MUSHNAT) y el Museo de la Universidad de San Carlos de Guatemala (MUSAC). Para la recolección de los hongos microscópicos se utilizó la técnica volumétrica por impactación haciendo uso de un biocolector. Los muestreos fueron realizados de octubre de 2011 a marzo de 2012, la identificación microscópica se realizó por medio de preparaciones con azul de lactofenol y para la identificación de levaduras se utilizó el API 20C AUX. Los resultados obtenidos en los ambientes Micoteca Licenciado Rúben Mayorga Peralta indican que la mayor concentración fúngica fue de 1,780, (unidad formadora de colonias por metro cúbico UFC/m3) en el exterior y para el interior fue de 1,270 UFC/m3, en el caso del Herbario BIGU en el exterior fue de 2,790 UFC/m3y en el interior de 1,450 UFC/m3, para el MUSAC la mayor concentración observada fue de 990 UFC/m3 para el exterior y de 1,010 UFC/m3 para el interior, y para el MUSHNAT en el caso del ambiente exterior fue de 1,630 UFC/m3 y para el interior fue de 2,850 UFC/m3. Los géneros predominantes durante los muestreos en ambos ambientes en todas las áreas muestreadas fueron Penicillium sp., Cladosporium sp. y Aspergillus sp. Se logró el aislamiento de otros géneros fúngicos de gran importancia Fusarium sp. y Paecilomyces sp. Se llevó a cabo la elaboración de una guía que contiene información acerca de procedimientos de limpieza y bioseguridad acorde a la infraestructura y materia prima de cada establecimiento.


Air quality was determined both inside and outside the Micoteca Licenciado Rubén Mayorga Peralta (MICG), the Herbarium of the School of Biology (BIGU), the Museum of Natural History (MUSHNAT) and the Museum of the University of San Carlos of Guatemala (MUSAC). Volumetric sampling (impaction) with a bio-colector was used to gather microscopic fungi. The samples were collected from Oct 2011 to Mar 2012. Microscopic identification was performed using slides with lactophenol blue; while API 20C AUX was used for the identification of yeasts. The results obtained were 1,780 CFU/m3 outside and 1,270CFU/m3 inside for MICG; 2,790 CFU/m3 outside and 1,450 CFU/m3 inside for BIGU; 990CFU/m3 outside and 1,010 CFU/m3 inside for MUSAC, and finally 1,630 CFU/m3 outside and2,850 CFU/m3 inside for MUSHNAT. The predominant genera found in both environmentsof all sites were Penicillium sp., Cladosporium sp. and Aspergillus sp. It was also possible toisolate other extremely important fungal genera such as Fusarium sp. and Paecilomyces sp. A guide was developed with information about the proper cleaning and biosafety proceduresaccording to the infrastructure and raw materials of each site.

10.
Rev. salud pública ; 17(5): 1-1, set.-oct. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-769291

ABSTRACT

Objetivo Aislar e identificar microorganismos (bacterias y hongos) presentes en el aire de la zona urbana de la ciudad de Neiva en el periodo comprendido entre la época de sequía y la época de lluvias durante el año 2012 Materiales y Métodos Se emplearon dos métodos para la recolección de la muestra: sedimentación en placa y un bioimpactador M Air T de Millipore en los cuales se dispensaron los medios Agar tripticasa soya (ATS) para el crecimiento de bacterias y agar gentamicina-glucosa-extracto de levadura (GGY) para el crecimiento de hongos; como colorantes se emplearon la tinción de Gram y la tinción con azul de lactofenol. Cuando fue necesario se empleó KOH al 10 %. Resultados El género Aspergillus spp. y los bacilos grampositivos fueron los microorganismos predominantes en las distintas zonas de muestreo, mientras que los géneros Aureobasidium sp. y bacilos gramnegativos presentaron frecuencia de aparición ocasional y rara, ya que no son considerados microorganismos propios del aire. Conclusiones La carga microbiana fue mayor en la época de sequía con respecto a la época de lluvias, presentándose más crecimiento bacteriano que fúngico en las dos temporadas del año. Con el uso del bioimpactador se observó mayor crecimiento tanto de bacterias como de hongos en comparación con el método de sedimentación en placa.(AU)


Objective To isolate and identify microorganisms (bacteria and fungi) present in the air in the city of Neiva between the dry and rainy seasons of 2012. Materials and Methods Two methods were used for sample collection: sedimentation plates and the bio-impactor Millipore M Air T in which the following culture media were dispensed: agar tripticase soy (ATS) for bacteria growth, and agar gentamicin-glucose-yeast extract for fungi growth. The dyes employed included Gram stain and lactophenol blue stain. When necessary 10 % KOH was also used. Results According to the frequencies of occurrence, Aspergillus spp. and Gram-positive bacilli were the predominant microorganisms in the different sampling areas. The genus Aureobasidium sp. and Gram-negative bacilli showed occasional, and rare occurrence frequency since they are not considered to be air-born microorganisms. Conclusions The microbial load was higher in the dry season than in the rainy season, appearing more fungal bacterial growth in both seasons of the year. With the use of the Bio-impactor, increased growth of both bacteria and fungi could be observed as compared to the sedimentation plate method.(AU)


Subject(s)
Bacteria/isolation & purification , Sedimentation , Air Pollution/analysis , Fungi/isolation & purification , Data Collection/methods , Microbiological Techniques/methods , Colombia
11.
Rev. saúde pública ; 47(6): 1059-1068, dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-702729

ABSTRACT

OBJETIVO : Analisar a qualidade do ar em escolas de educação básica e suas condições estruturais e funcionais. MÉTODOS : Foi avaliada a qualidade do ar de 51 escolas (81 salas de aula) de educação básica da cidade de Coimbra, Portugal, tanto na parte interior das salas como na exterior, durante as quatro estações do ano, de 2010 a 2011. Foram avaliadas a temperatura (Tº), umidade relativa (Hr), concentrações de monóxido de carbono (CO), dióxido de carbono (CO 2 ), ozona (O 3 ), dióxido de nitrogênio (NO 2 ), dióxido de enxofre (SO 2 ), compostos orgânicos voláteis (COV), formaldeído e material particulado (PM 10 ), de novembro de 2010 a fevereiro de 2011 (outono/inverno) e de março de 2011 a junho de 2011 (primavera/verão). Procedeu-se ao preenchimento de uma grelha de caracterização das condições estruturais e funcionais das escolas. Aplicaram-se os testes estatísticos t- Student para amostras emparelhadas e o teste t de Wilcoxon. RESULTADOS : Em 47 escolas, as concentrações médias de CO 2 encontravam-se acima da concentração máxima de referência (984 ppm) mencionada na legislação portuguesa. Os valores máximos de concentração encontrados no interior das salas foram críticos, principalmente no outono/inverno (5.320 ppm). As concentrações médias de COV e de PM 10 no interior ultrapassaram a concentração máxima de referência legislada em algumas escolas. Não foram detetados valores relevantes (risco) de CO, formaldeído, NO 2 , SO 2 e O 3 . CONCLUSÕES : Houve maior concentração de poluentes no interior das salas, comparativamente com o exterior. A inadequada ventilação está associada à elevada concentração de CO 2 nas salas de aula. .


OBJETIVO : Analizar la calidad del aire en escuelas de educación básica y sus condiciones estructurales y funcionales. MÉTODOS : Se evaluó la calidad del aire de 51 escuelas (81 salas de aula) de educación básica de la ciudad de Coimbra, Portugal, tanto en el interior de las salas como en el exterior, durante las cuatro estaciones del año, de 2010 a 2011. Se evaluaron la temperatura (T°), humedad relativa (Hr), concentraciones de monóxido de carbono (CO), dióxido de carbono (CO2), ozono (O3), dióxido de nitrógeno (NO2), dióxido de azufre (SO2), compuestos orgánicos volátiles (COV), formaldehido (HCHO) y material particulado (PM10), de noviembre de 2010 a febrero de 2011 (otoño/invierno) y de marzo de 2011 a junio de 2011 (primavera/verano). Se procedió a llenar una tabla de caracterización de las condiciones estructurales y funcionales de las escuelas. Se aplicaron las pruebas estadísticas t-Student para muestras pareadas y la prueba t de Wilcoxon. RESULTADOS : En 47 escuelas, las concentraciones promedio de CO2 estaban por encima de la concentración máxima de referencia (984 ppm) mencionada en la legislación portuguesa. Los valores máximos de concentración encontrados en el interior de las salas fueron críticos, principalmente en el otoño/invierno (5.320 ppm). Las concentraciones promedio de COV y de PM10 en el interior sobrepasaron la concentración máxima de referencia legislada en algunas escuelas. No fueron detectados valores relevantes (riesgo) de CO, HCHO, NO2, SO2 y O3. CONCLUSIONES : Hubo mayor concentración de contaminantes en el interior de las salas, en comparación con el exterior. La inadecuada ventilación está asociada con la elevada concentración de CO2 en las salas de aula. .


OBJECTIVE : To analyze the air quality in elementary schools and their structural and functional conditions. METHODS : Air quality in 51 elementary schools (81 classrooms) in the city of Coimbra, Portugal, both inside and outside of the rooms was evaluated during the four seasons, from 2010 to 2011. Temperature (T°), relative humidity (Hr), concentrations of carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), compounds were evaluated, as were volatile organics (VOC), formaldehyde and particulate matter (PM10), from November 2010 to February 2011 (autumn/winter) and March 2011 to June 2011 (spring/summer). A grid characterizing the structural and functional conditions of the schools was created. The statistical Student t test for paired samples and the Wilcoxon t test were applied. RESULTS : In 47 schools, the average CO2concentrations were above the maximum reference concentration (984 ppm) mentioned in Portuguese legislation. The maximum concentration values found inside the rooms were critical, especially in the fall/winter (5,320 ppm). In some schools the average concentrations of VOC and PM10within the maximum concentration exceeded the reference legislated. The values (risk) of CO, formaldehyde, NO2, SO2and O3detected were not relevant. CONCLUSIONS : There was a higher concentration of pollutants inside the rooms compared with outside. Inadequate ventilation is associated with high CO2concentration in the classroom. .


Subject(s)
Air Pollutants/analysis , Air Pollution, Indoor/analysis , Schools/statistics & numerical data , Air Pollutants/chemistry , Air Pollution, Indoor/statistics & numerical data , Carbon Dioxide/analysis , Carbon Monoxide/analysis , Nitrogen Dioxide/analysis , Portugal , Risk Assessment , Seasons
12.
Rev. biol. trop ; 61(2): 557-563, Jun. 2013. ilus, mapas
Article in English | LILACS | ID: lil-675451

ABSTRACT

There are no studies of air pollution bio-indicators based on Geographic Information Systems (GIS) for Costa Rica. In this study we present the results of a project that analyzed tree trunk lichens as bioindicators of air pollution in 40 urban parks located along the passage of wind through the city of San Jose in 2008 and 2009. The data were processed with GIS and are presented in an easy to understand color coded isoline map. Our results are consistent with the generally accepted view that lichens respond to the movement of air masses, decreasing their cover in the polluted areas. Furthermore, lichen cover matched the concentration of atmospheric nitrogen oxides from a previous study of the same area. Our maps should be incorporated to urban regulatory plans for the city of San José to zone the location of schools, hospitals and other facilities in need of clean air and to inexpensively assess the risk for breast cancer and respiratory diseases in several neighborhoods throughout the city.


En Costa Rica no hay estudios de la contaminación del aire basados en los Sistemas de Información Geográfica (SIG). En este artículo se muestran los resultados de un estudio que analizó los líquenes en troncos de árboles de 40 parques urbanos situados a lo largo del paso del viento por la ciudad de San José, durante los años 2008 y 2009. Los datos fueron procesados mediante SIG y se presentan de manera simple en un mapa de isolíneas con códigos de color. Los resultados concuerdan con la opinión generalmente aceptada de que los líquenes reaccionan ante la circulación de masas de aire al decrecer su cobertura en las zonas más contaminadas. Además, la cobertura de líquenes coincidió con la concentración de óxidos de nitrógeno en la atmósfera, tomada de un estudio previo en la misma zona. Nuestros mapas deben incorporarse en los planes reguladores de la ciudad de San José para zonificar la ubicación de escuelas, hospitales y otros edificios que demanden aire puro, así como para identificar de manera económica el riesgo de cáncer de pecho y enfermedades respiratorias en los diferentes barrios de la ciudad.


Subject(s)
Air Pollutants/analysis , Air Pollution/analysis , Cities , Environmental Monitoring/methods , Geographic Information Systems , Lichens/metabolism , Costa Rica
13.
Rev. salud pública ; 15(1): 66-79, ene.-feb. 2013. ilus, graf, tab
Article in Spanish | LILACS | ID: lil-703423

ABSTRACT

Objetivos Establecer la prevalencia de síntomas respiratorios y enfermedad respiratoria en niños menores de 12 años de municipios de influencia de la zona carbonífera del departamento del Cesar y posibles factores asociados. Métodos Estudio transversal en 1 627 niños menores de 10 años habitantes de municipios carboneros del Cesar expuestos a diferentes niveles de MP10 en los años 2008-2010, en quienes se midieron enfermedades y síntomas respiratorios relacionados con exposición a PM10, buscando asociación con diferentes zonas de exposición al material particulado. Resultados Niños de corregimientos próximos a depósitos mineros y de corregimientos con tráfico tuvieron mayor proporción de casos probables de asma; mientras que los del corregimiento con tráfico se ausentaron más días por enfermedad respiratoria aguda; se encontró mayor frecuencia de síntomas respiratorios en niños expuestos al humo de cigarrillo o de leña intramurales, niños de viviendas con paredes de bareque o adobe, tenencia de animales, presencia de humedad en las viviendas, vehículos de carga a menos de 100 m de la vivienda; vivir en zonas con tráfico aumentó el riesgo de presentar síntomas respiratorios, enfermedad respiratoria aguda y ausentismo escolar. Discusión Todos los efectos estudiados estuvieron asociados a condiciones intramurales, factores del entorno cercano o individuales, coincidiendo con lo encontrado en estudios similares de salud y contaminación del aire. Se sugiere la creación de estrategias y políticas regionales para el control y monitoreo de la calidad del aire y la salud de los habitantes del departamento del Cesar.


Objectives Establishing the prevalence of respiratory symptoms and disease in children aged less than 12 years-old living within the Cesar department's coal-mining area and possible associated factors. Methods This was a cross-sectional study of 1,627 children aged less than 10 years-old living in and near coal-mining areas in the Cesar department who were exposed to different levels of PM10 from 2008-2010; their PM10 exposure-related symptoms and respiratory diseases were measured, seeking an association with living in areas exposed to particulate material. Results Children living in areas close to coal-mining activity which also had high traffic volume had a higher rate of probable cases of asthma; those living in areas with traffic (not no coal-mining) were absent from school for more days due to acute respiratory disease. Respiratory symptoms were most commonly found in children experiencing living conditions which exposed them to cigarette or firewood smoke indoors, living in houses made with wattle and daub or adobe walls, living where animals were kept, living in damp housing and diesel-powered dump trucks operating within 100 m or less of their housing. Living in areas having high traffic volume increased the risk of respiratory symptoms, acute respiratory disease and being absent from school. Discussion All the effects studied were associated with intramural conditions, individual factors or those associated with the immediate surroundings thereby coinciding with results found in similar studies regarding air pollution and health. It is thus suggested that regional strategies and policy be created for controlling and monitoring the air quality and health of people living in the Cesar department.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Air Pollution/adverse effects , Coal Mining , Environmental Exposure/adverse effects , Particulate Matter/adverse effects , Respiration Disorders/chemically induced , Respiration Disorders/epidemiology , Colombia/epidemiology , Cross-Sectional Studies , Prevalence , Rural Health , Urban Health
14.
Rev. luna azul ; (34): 195-213, ene.-jun. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-659390

ABSTRACT

El material particulado es uno de los contaminantes atmosféricos más estudiados en el mundo, este se define como el conjunto de partículas sólidas y/o líquidas (a excepción del agua pura) presentes en suspensión en la atmósfera (Mészáros, 1999), que se originan a partir de una gran variedad de fuentes naturales o antropogénicas y poseen un amplio rango de propiedades morfológicas, físicas, químicas y termodinámicas. La presencia en la atmósfera de este contaminante ocasiona variedad de impactos a la vegetación, materiales y el hombre, entre ellos, la disminución visual en la atmósfera, causada por la absorción y dispersión de la luz (Chen,Ying &Kleeman,2009).Además, la presencia del material particulado está asociada con el incremento del riesgo de muerte por causas cardiopulmonares en muestras de adultos (Pope, 2004) Es necesario, además de realizar mediciones de la concentración de este contaminante, evaluar su comportamiento en el espacio y el tiempo, asociándolo con los fenómenos meteorológicos, composición química y origen, los cuales permitan orientar estrategias de control y realizar seguimiento por parte de las autoridades ambientales interesadas. Este artículo presenta una revisión bibliográfica de los impactos asociados con partículas presentes en la atmósfera, los equipos para su monitoreo, aplicaciones tecnológicas complementarias y tecnologías de control.


Particulate matter is one of the most studied atmospheric pollutants around the world. It is defined as the set of solid or liquid particles (except plain water) which are present in suspension in the atmosphere (Mészáros, 1999), and that originate from a variety of natural or anthropogenic sources and have a wide range of morphological, physical, chemical and thermodynamic properties. The presence of this pollutant in the atmosphere causes a variety of impacts on vegetation, materials and human beings, including a visual decrease in the atmosphere caused by the absorption and diffusion of light (Chen, Ying & Kleeman, 2009). Furthermore, the presence of particulate matter is associated with increased risk of death from cardiopulmonary causes in samples of adults (Pope, 2004) Besides measuring this pollutant concentrations, it is necessary to assess its behavior in space and time associating it with meteorological phenomena, chemical composition, and origin of which allows the orientation of control strategies and the performance of follow-up activities by the environmental authorities concerned. This article presents a literature review of the impacts associated with particles present in the atmosphere, the equipment for monitoring them, complementary technological applications and control technologies.


Subject(s)
Humans , Air Pollution , Pollutants Dispersion , Particulate Matter
15.
Kasmera ; 39(1): 59-67, ene.-jun. 2011. tab, graf
Article in Spanish | LILACS | ID: lil-654000

ABSTRACT

Los establecimientos de atención en salud son entornos donde se congregan pacientes que en menor o mayor grado presentan compromisos inmunológicos. En este contexto, el ambiente hospitalario resulta un espacio donde podrían adquirir infecciones nosocomiales con el consiguiente deterioro del cuadro clínico preexistente. En el presente estudio se realizaron evaluaciones en ambientes hospitalarios de centros de salud ubicados en la ciudad de Valencia, Venezuela, tomando en cuenta áreas críticas como quirófanos. Para la captación de las muestras se tomó en cuenta las metodologías establecidas en las Normas Técnicas Españolas. La captación del aire sobre los medios de cultivo Nutritivoy Sabouraud se incubaron a 37°C de 24-72 horas, para determinar UFC/m3 de aire. Conjuntamente se midió la temperatura y humedad relativa. La identificación microbiológica se realizó utilizando galerias bioquímicas automatizadas (API). De los 6 centros hospitalarios evaluados, 5 quirófanos presentaron más de 10 UFC/m3 de aerobios mesófilos y más de 20 UFC/m3 de población fúngica, cuyo rango debería ser menor a 10UFC/m3. Los microorganismos identificados con mayor frecuencia fueron: Staphylococcus spp, Pseudomonas aeruginosa, Bacillus spp., Acinetobacter lowfii, Aspergillus nidulans, A. terreus y Geotrichum candidum. Las medidas de temperatura fueron mayores a 20°C y la humedad relativa mayor a 45%, siendo el rango establecido por la NTP 409 para la temperatura entre 15-18°C, y 50-70% en cuanto a la humedad relativa. Se infiere que existe poco compromiso en aplicar las medidas correctas para cumplir a cabalidad con las normas de manipulación de pacientes en áreas críticas, lo que propicia un entorno favorable para el desarrollo microbiano, además de factores como temperatura, humedad relativa, sistemas de climatización, que no cumplen con lo indicado según las normas técnicas Internacionales


Health center facilities are areas where patients who have a greater or lesser degree of immunological compromise congregate. In this context, the hospital environment is a space where nosocomial diseases could be acquired causing deterioration of the preexistent clinical condition. This study carried out evaluations in hospital environments at health centers in the city of Valencia, Venezuela, taking into account critical areas such as operating theatres. For sample collection, methodologies established by the Spanish Technical Standards were taken into account. The air samples taken over Nutritivo and Sabouraud cultivation media were incubated at 37°C for 24-72 hours, to determine the UFC/m3 for the air. Following a 24-hour incubation at 37°C, the bacterial charges (UFC/m3) were determined. Additionally, temperature and relative humidity were measured. Taxonomical identification was achieved through a computerized biochemical test (API galleries). Five out of the six health centers evidenced more than 10UFC/m3 and 20 UFC/m3 for the bacterial and fungal charges, respectively. These values are higher than those allowed by official legislation. The most frequently detected microorganisms were Staphylococcus spp, Pseudomonas aeruginosa, Bacillus spp., Acinetobacter lowfii, Aspergillus nidulans, A. terreus and Geotrichum candidum. The temperature and relative humidity were always higher than 20°C and 45%, whereas ranges established by the NTP 409 norm are 15-18ºC and 50-70%, respectively. It seems there is little commitment to applying correct measures to comply fully with standards for patient handling in critical areas, favoring an environment conducive to microbial development, as well as factors such as temperature, relative humidity and air conditioning systems, which do not comply with what is indicated in international technical standards


Subject(s)
Air Pollution , Aerosols/radiation effects , Aerosols/toxicity , Environmental Quality/prevention & control , Environment , Health Centers
16.
Cienc. Trab ; 12(37): 349-354, jul.-sept. 2010. ilus, tab
Article in Spanish | LILACS | ID: lil-579570

ABSTRACT

Nuestra experiencia en evaluación de sistemas de ventilación existentes en edificios destinados a trabajos de oficina nos ha permitido detectar con una frecuencia relativamente alta problemas relacionados con el diseño y gestión de estos sistemas, que dificultan la obtención de ambientes sanos y confortables. En cuanto al diseño, éste requiere considerar las bases, parámetros y estándares que permitan obtener de ellos las condiciones que las personas necesitan y, una vez logrado lo anterior, la gestión correspondiente para controlar su aplicación y existencia permanente, que implica la evaluación periódica de los parámetros a través de mediciones y dispositivos de observación, así como de regulación y mantención de sus elementos constituyentes. Los resultados de las mediciones de estos parámetros deben ser verificados con estándares nacionales o internacionales reconocidos, utilizados en el diseño.


Our experience in evaluation of ventilation systems installed in buildings intended for offices has allowed us to detect rather frequent problems related to the design and management of these systems, which hamper the achievement of healthy and comfortable environments. With regard to design, it is necessary to consider the bases, parameters and standards that allow the achievement of the conditions that people require, and once this has been achieved, the corresponding management for controlling its application and continuous existence that implies the periodic evaluation of parameters through measurements and observation devices, as well as the regulation and maintenance of its constituent elements. The results of the measurements of these parameters must be verified with recognized national or international standards used in the design.


Subject(s)
Air Quality Standards , Air Pollution, Indoor/analysis , Ventilation/standards
17.
Rev. chil. enferm. respir ; 26(1): 16-25, mar. 2010. ilus
Article in Spanish | LILACS | ID: lil-556753

ABSTRACT

The term air pollution comprises a wide variety of chemical and biological components of the outdoor and indoor atmosphere. Air pollution and its effect on human health is critically reviewed in this article with emphasis in the situation of inhabitants of Chilean cities with critical high levels of atmospheric pollution. Atmospheric contaminants that are hazardous for the human health are breathable particulate matter (PM10;PM2,5 and PM0,1) and gaseous chemicals such as nitrogen dioxide, ozone, sulphur dioxide and carbon monoxide. Indoor air contains a variety of noxious compounds derived from multiple sources, being cigarette smoking, heating and cooking appliances, and biological agents and its sub-products the principal ones. Exposure to air pollutants can increase not only morbidity but also mortality rate as well as increasing the number of hospital admissions for patients with respiratory or cardiovascular symptoms. Air pollution is important in determining the quality of life particularly in infants, ageing persons and patients affected by respiratory and cardiovascular diseases. Health professionals should advocate for a cleaner outdoor and indoor atmosphere through the dissemination of our knowledge about the respiratory and non-respiratory effects of air contamination.


El término contaminación del aire incluye una amplia variedad de componentes químicos y biológicos de la atmósfera intra y extradomiciliaria. Este artículo intenta realizar una revisión crítica de los efectos de la contaminación intra y extradomiciliaria sobre la salud humana, poniendo especial énfasis en la situación de los habitantes de ciudades chilenas con niveles críticamente altos de contaminación atmosférica. Los contaminantes atmosféricos riesgosos para la salud humana son el material particulado inhalable (PM10; PM2,5 y PM0,1) y compuestos químicos gaseosos tales como dióxido de nitrógeno, ozono, dióxido de azufre y monóxido de carbono. El aire intradomiciliario contiene una variedad de compuestos nocivos que derivan de múltiples fuentes. Las más importantes son el humo de cigarrillo, artefactos de calefacción y para cocción de alimentos y los agentes biológicos y sus sub-productos. La exposición a contaminantes del aire no solo puede aumentar la tasa de morbilidad sino la tasa de mortalidad como también puede aumentar el número de ingresos hospitalarios de pacientes con síntomas respiratorios y cardiovasculares. La contaminación del aire es importante en la determinación de la calidad de vida de niños menores, ancianos y en pacientes con enfermedades respiratorias y cardiovasculares. Los profesionales de la salud deberían abogar por una atmósfera intra y extradomiciliaria más limpia a través de la difusión del conocimiento que disponemos sobre los efectos respiratorios y no respiratorios de la contaminación del aire.


Subject(s)
Humans , Air Quality Standards , Air Pollution/adverse effects , Chile , Air Pollution, Indoor/adverse effects , Air Pollutants/adverse effects , Particulate Matter/adverse effects , Seasons , Cardiovascular System/physiopathology , Respiratory System/physiopathology , Urban Area
18.
Salud pública Méx ; 52(supl.2): S157-S167, 2010. graf, tab
Article in English | LILACS | ID: lil-571808

ABSTRACT

Objective. To evaluate indoor air pollution in hospitality venues in Argentina. Material and Methods. PM2.5 levels were measured in a convenience sample of venues in 15 cities with different legislative contexts following a protocol developed by Roswell Park Cancer Institute. Results. 554 samples were collected. Across all 5 smokefree cities the mean PM2.5 level was lower during daytime vs. evening hours, 24 vs. 98 PM2.5 respectively (p=.012). In the three cities evaluated before and after legislation, PM2.5 levels decreased dramatically (p<0.001 each). Overall, PM2.5 levels were 5 times higher in cities with no legislation vs. smokefree cities (p<0.001). In cities with designated smoking areas, PM2.5 levels were not statistically different between smoking and non-smoking areas (p=0.272). Non-smoking areas had significantly higher PM2.5 levels compared to 100 percent smokefree venues in the same city (twofold higher) (p=0.017). Conclusions. Most of the participating cities in this study had significantly lower PM2.5 levels after the implementation of 100 percent smokefree legislation. Hence, it represents a useful tool to promote 100 percent smokefree policies in Argentina.


Objetivo. Evaluar la polución ambiental del sector gastronómico en Argentina. Material y métodos. Se midieron los niveles de partículas respirables (PM2.5) en una muestra por conveniencia de establecimientos de 15 ciudades con diferente legislación, siguiendo un protocolo del Instituto de Cáncer Roswell Park. Resultados. Se recolectaron 554 muestras. En cinco ciudades libres de humo (CLH) la media de PM2.5 durante el día fue baja y menor a la observada durante la noche, 24 vs. 98 PM2.5 respectivamente (p=.012). En las tres ciudades evaluadas antes y después de la legislación, las PM2.5 disminuyeron drásticamente (p<0.001 cada una). Las PM2.5 fueron cinco veces mayores en ciudades sin legislación comparadas con CLH (p<0.001). En ciudades con restricción parcial, no hubo diferencia significativa entre las PM2.5 en el sector fumador y no fumador (p=0.272). Los sectores no fumadores tuvieron niveles PM2.5 significativamente más altos comparados con los lugares 100 por ciento libres de humo de la misma ciudad (p= 0.017). Conclusiones. La mayoría de las ciudades participantes en este estudio tuvieron niveles PM2.5 significativamente más bajos tras la implementación de leyes pro ambientes 100 por ciento libres de humo de tabaco, por lo que representa una herramienta útil para promover legislación 100 por ciento libre de humo en Argentina.


Subject(s)
Air Pollution, Indoor/analysis , Air Pollution, Indoor/legislation & jurisprudence , Environmental Monitoring , Health Policy/legislation & jurisprudence , Smoking/legislation & jurisprudence , Smoking/prevention & control , Tobacco Smoke Pollution/analysis , Tobacco Smoke Pollution/legislation & jurisprudence , Air Pollution, Indoor/prevention & control , Argentina , Tobacco Smoke Pollution/prevention & control , Urban Health
19.
Rev. cuba. salud pública ; 33(4)oct.-dic. 2007. graf
Article in Spanish | LILACS | ID: lil-479252

ABSTRACT

La población de Acre, en su parte este y norte, sufre el efecto derivado de las altas concentraciones de humo en el aire debido a las quemadas de la biomasa forestal. Esta polución viola las normas establecidas sobre calidad del aire. De junio a septiembre de cada año, durante la estación de seca, el humo ocasiona enfermedades y malestares en la población. Para estudiar este efecto se realizaron mediciones de la calidad del aire mediante tres métodos independientes: nefelometría, aetalometría y radiometría solar; y observaciones de su impacto sobre la salud, a partir de la aplicación de una encuesta a una muestra aleatoria de cincuenta individuos, moradores de áreas periféricas de la ciudad de Rio Branco. Se encontró que prácticamente el 100 por ciento de los habitantes pobres padecen de enfermedades respiratorias y oculares como consecuencia de la polución del aire, ocasionada por las quemadas forestales en la Amazonia, particularmente durante la seca de 2005.


The Acre population living in the East and the North suffers the effect of high smoke concentrations in the air due to forest biomass burning. This pollution is against the set standards on the air quality. Every year, during the dry season from June to September, smoke causes diseases and discomfort that are affecting the population. With the objective of studying this impact, the air quality was measured by means of three independent methods, namely, nephelometry, aethalometer and solar radiometry; and also observations on the impact of the air quality on health based on the administration of a survey to a random sample of 50 people, who lived in the surrounding areas of Rio Branco city. The general objective was to find out how high smoke concentrations affected that population's health; particularly in the dry season in 2005. As a consequence, practically 100 percent of poor inhabitants suffered from refractory and occular diseases caused by air pollution resulting from forest biomass burnings in the Amazons region.

SELECTION OF CITATIONS
SEARCH DETAIL